The KM-350MWJ is capable of producing approximately 414 lbs of crescent cubed ice. Our efficient double-sided KMEdge stainless steel evaporators create our unique crescent shaped ice cubes. It is the purest and hardest ice on the market and is a perfect fit for a wide range of applications. This Water-cooled, Slim Line Modular icemaker features a CycleSaver™ design and includes the EverCheck™ alert system making the unit energy efficient and simple to maintain. The KM-350MWJ requires a Single phase, 115v/60/1, 3 wire, including ground. Must be hardwired at site, no cord/plug included. Compatible bins & dispensers, sold separately: B-250, B-300, B-500, B-700, B-800, B-900, B-1150, B-1300, DB-130H, DB-200H, DM-200B. Please consult the Specification Sheet for additional details. Replaces KM-340MWJ.
KM-350MWJ, Crescent Cuber Icemaker, Water-cooled Features
- Dimensions: 22″ W x 27-3/8″ D x 28″ H
- Up to 414 lbs of ice produced per 24 hours
- Mount 2 units side-by-side for 2x the ice production
- Produces crescent shaped ice cubes
- Durable stainless steel exterior
- Compatible bins & dispensers, sold separately: B-250, B-300, B-500, B-700, B-800, B-900, B-1150, B-1300, DB-130H, DB-200H, DM-200B
- EverCheck™ alert system
- CycleSaver™ design
- Protected by H-GUARD Plus Antimicrobial Agent
- R-404A refrigerant (11.6 oz. / 329 g)
- Heat Rejection:7500 BTU/hr
- Ambient temperature range: 45 – 100°F
- Water temperature range: 45 – 90°F
- Water pressure: 10 – 113psig
- Voltage range: 104 – 127V
- 7.5 amps (15 Amp Max fuse)
- 4.9 kwh/100 lbs.@ 90/70
- Single phase, 115v/60/1, 3 wire, including ground. Must be hardwired at site, no cord/plug included
- Clean ice and easy maintenance lead to longer unit life span
KM-350MWJ, Crescent Cuber Icemaker, Water-cooled Specification
- Electrical Specs: Single phase, 115v/60/1, 3 wire, including ground. Must be hardwired at site, no cord/plug included, Amperage: 7.5, Max Fuse/HACR Breaker: 15 A
- Plumbing Specs: 1/2" FPT Inlet, Minimum 1/4" Nominal ID Copper Water Tubing or Equivalent, 3/4" FPT Outlet, Minimum 3/4" Nominal ID Drain Hard Pipe or Equivalent, Minimum 1/4" Nominal ID Drain Hard Pipe or Equivalent
- Utility Consumption: 4.9 kWh per 100 lbs @ 90/70, 15.5 gal of Potable Water per 100 lbs @ 90/70
- Operating Limits: Ambient Temp Range: 45 - 100°F, Water Temp Range: 45 - 90°F, Water Pressure: 10 - 113psig, Voltage Range: 104 - 127V, Heat Rejection: 7500 BTU/hr, Refrigerant Charge: R-404A, (11.6 oz. / 329 g)